Product Description
2014-2015 880 Maxxus/Aspen 3-pump NT systems with PermaClear and Smart Logic (IC Processor Rev. 3.1A included)
Can be used in place of 6600-155, 6600-160 and 6600-398
Tech Tip
Jumper settings are as follows:
JP19 Jumper Bank
JP19-1 - On - Celcius, Off - Fahrenheit
JP19-3 - On - 50Hz, Off - 60Hz
JP19-5 - On - LED Lights, Off - Incandescent Lights
JP19-7, 9, and 11 are not used
JP9 Jumper Bank
JP9-1 - On - Enables Trouble Log, Off - Disables Trouble Log
JP9-3 - On - Enables ILOC, Off - Disables ILOC
JP9-5 - NOT USED
JP9-7 - On - 60A Logic Allows 2 Pumps on w/Heater, Off - 50A Logic Forces Heater Off When More Than 1 Pump is ON
JP9-9 - On - Enables Pump 2 on -728/-730 pcb's and Pump 3 on -392 pcb, Off - Disables
JP9-11 - On - 40A Logic Forces Heater off w/ Any Pump in Hi, Off - Disables
JP9-13 - On - Allows Only 1 Pump w/Blower to Operate at a Time, Off - Blower, Pump 1, Pump 2 Can Operate at the Same Time
JP9-15 - On - Recall All Factory Settings, Off - The Jumper Must Remain Off During Normal Operation